BEACON eSpace at Jet Propulsion Laboratory >
JPL Technical Report Server >
JPL TRS 1992+ >
Please use this identifier to cite or link to this item:
http://hdl.handle.net/2014/40168
|
| Title: | Magnetometer based on the opto-electronic oscillator |
| Authors: | Matsko, Andrey B. Strekalov, Dmitry Maleki, Lute |
| Keywords: | magnetometer Opto-Electronic Oscillator (OEO) coherence |
| Issue Date: | 1-Dec-2005 |
| Publisher: | Pasadena, CA : Jet Propulsion Laboratory, National Aeronautics and Space Administration, 2005. |
| Citation: | MRS Fall Meeting, Boston, Massachusetts, December 1, 2005. |
| Abstract: | We theoretically propose and discuss properties of two schemes of an all-optical self-oscillating magnetometer based on an opto-electronic oscillator stabilized with an atomic vapor cell. Proof of the principle DC magnetic field measurements characterized with 2 x 10¯<superscript> 7 G sensitivity and 1 - 1000 mG dynamic range in one of the schemes are demonstrated. |
| URI: | http://hdl.handle.net/2014/40168 |
| Appears in Collections: | JPL TRS 1992+
|