| Title: | Recent Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS) |
| Authors: | Chrien, T. Eastwood, M. Green, R. Sarture, C. |
| Issue Date: | 26-Nov-1995 |
| Citation: | International Symposium on Spectral Sensing Research 1995 Melbourne, Australia |
| Abstract: | Several improvements have been made to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS) since 1994--new focal plane arrays, a new analog and digital chain and an onboard calibration lamp controlled by radiance feedback. These changes increased the signal-to- noise ratio by 2 to 3 times, eliminated noise spikes and the need for spectral sampling, and greatly reduced dark-current noise. |